Glass fire doors
Rparts MC 45 & C60
Fire-rated glazed façade with a 45 mm sightline, or 60 mm for long spans.
Reply within 48 business hours · +212 (0) 661 786 437
Description
This glazed façade cuts the visible face to 45 mm. For long spans the grid goes to 60 mm so a fire rating can be kept.
Where it is used
Atria, lobbies and internal curtain walls use it when the framing must stay fine. Outer caps multiply the finishes.
Technical characteristics
- 45 mm sightline, or 60 mm for large bays
- E, EW and Ei ratings possible on the 45 mm grid
- Ei rating on the 60 mm grid
- High sealing and several outer caps
- Tests EN 1364-1 and EN 1634-1, classification EN 13501-2
Standards and installation
Span, glass weight and the rating required set the grid. A façade and its access doors are justified in the same test file.